D.P.Engineers
D.P.Engineers
Gandhi Nagar Jheel, Delhi
GST No. 07APKPS1463E1ZT
TrustSEAL Verified
Call 0794256114992% Response Rate
SEND EMAIL
 

Aerosense Clean Room Monitor Distribution Channels partner in india

Leading Manufacturer of aerosense differential pressure gauges in wholesale dealers supplies hubli karnataka, aerosense series adprht clean room monitor and aerosense series cdt-100 carbon dioxide transmitter from Delhi.

Aerosense Differential Pressure Gauges in wholesale dealers supplies Hubli Karnataka

Aerosense Differential Pressure Gauges in wholesale dealers supplies Hubli Karnataka
  • Aerosense Differential Pressure Gauges in wholesale dealers supplies Hubli Karnataka
Get Best Quote
Approx. Price: Rs 4,500 / PieceGet Latest Price

Product Details:

Dial Size4 inch / 100 mm
BrandAerosense
UsePharmaceutical Industries
Display TypeAnalog
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry

Request
Callback
Yes! I am Interested

Aerosense Series ADPRHT Clean Room Monitor

Aerosense Series ADPRHT Clean Room Monitor
  • Aerosense Series ADPRHT Clean Room Monitor
  • Aerosense Series ADPRHT Clean Room Monitor
  • Aerosense Series ADPRHT Clean Room Monitor
  • Aerosense Series ADPRHT Clean Room Monitor
  • Aerosense Series ADPRHT Clean Room Monitor
  • Aerosense Series ADPRHT Clean Room Monitor
  • Aerosense Series ADPRHT Clean Room Monitor
Get Best Quote
Approx. Price: Rs 24,500 / PieceGet Latest Price
Product Brochure

Product Details:

BrandAerosense
Usage/ApplicationPharma Cleanrooms, Hvac, Environmental, Pharma Machinery, Across Filters, Hospital Isolation Room Et
Tempreture0 to 100 %
Relative Humidity0 to +25.0 mm
Accurecy+-0.5 C
Display Height Options0.4" High Standard
MountingWall Mounting
Dimensions74(W) x 72(H) x 40(D) mm

Aerosense Series ADPRHT Clean Room MonitorSeries ADPRHT Clean Room MonitorMulti-Parameter Display/Transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Series ADPRHT, Multi-parameter display/transmitter measures Differential Pressure, Humidity, Temperature and optional clock. Panel mount/rectangular type cut out for modular wall mounting with stainless steel front plate. Built-in high and low buzzer alarm for process set parameter.Product Applications:Pharma Cleanrooms, HVAC, Environmental, Pharma machinery, across filters, Hospital isolation room, operation theatres and laboratories.Precision of measurement in HVAC duct pressure application makes this instrument suitable for optimization of energy.Analog output & RS485 communication lead to easy integration with variable frequency drives and SCADA/BMS systems.Sensor Type:Polymer sensing for TemperatureCapacitive polymer sensing for Relative HumidityPiezo Resistive Sensor for Differential PressureRange:-30.0 to +50.0 Deg. C typical for Temperature0.0 to 100.0 % RH typical for Relative humidity0.0 to +25.0 mm. W.C. / 0 to 250 Pascals (Any other customized range as per user specifications)Resolution:Fixed 0.1 for both Temperature and Relative humidity 0.1 mm. W.C. or 1 Pascal for Differential PressureAccuracy:±0.5 C for -30 to 50° C for Temperature+/- 1.8% for 10 to 95% RH for Relative humidity+/- 0.5% F.S. for Differential PressureDisplay:3 Line Red 7 Segment LED Display.4 Digits for Differential Pressure on Line 1.4 Digits for % RH. (Humidity) on Line 2.4 Digits on Temperature (Deg. C) on Line 3.Display Height Options: -0.4” High Standard, Optional 1” High DisplayDifferential Pressure Entry: 2 Nos. 4 mm. Hose Nipples at top.Setting: By 4 keys on the front stainless steel panel.Buzzer: Integrated buzzer for Alarm in case of process violation of any of the 3 parametersSupply Voltage: 24VDC , 250mA
Mounting: Wall mounting / Modular Wall Mounting with Stainless Steel Front Flush Plate for Clean Rooms
Sensors: Integrated Humidity & Temperature Sensor flushed to front plate Built in differential pressure sensor with Brass HoseNipples (Chrome Plated) for Differential Pressure At Rear ( 4 mm x 2 Nos.) Optional External Humidity & Temperature Sensor
Communication: RS 485 Modbus Protocol (Optional)
Output: 4-20mA (Optional)
Dimension: Enclosure: 74(W) x 72(H) x 40(D) mm.Stainless Steel Front Plate: 110W x 90(H) mmEnclosure: M.S. Power Coated body with Stainless Steel Front Flush Plate for Modular Wall Mounting/Optional Brick Wall Mounting.Weight: 300 gms. Approx.
Request
Callback


Additional Information:

  • Delivery Time: 4-6 week
  • Packaging Details: Websites : www.dpengineers.in www.dpengineer.in www.dpengineers.co.in www.dpengineer.co.in www.dpengineersindia.com www.dpengineerindia.com www.dpengineersindia.in www.dpengineers.info www.dpengineer.info www.dp-engineers.com www.dpengineerindia.in www.dpengineersindia.net www.dpengineersdelhi.co.in www.dpengineersdelhi.com www.dpengineersdelhi.net
Yes! I am Interested

Aerosense Series CDT-100 Carbon Dioxide Transmitter

Aerosense Series CDT-100 Carbon Dioxide Transmitter
  • Aerosense Series CDT-100 Carbon Dioxide Transmitter
  • Aerosense Series CDT-100 Carbon Dioxide Transmitter
  • Aerosense Series CDT-100 Carbon Dioxide Transmitter
  • Aerosense Series CDT-100 Carbon Dioxide Transmitter
Get Best Quote
Approx. Price: Rs 19,500 / PieceGet Latest Price
Product Brochure

Product Details:

Display TypeDigital
BrandAerosense
ModelSeries CDT-100
Gas TypeNatural Gas
I deal inNew Only
UsageDemand Control Ventilation in schools,office buildings,hospitals and other indoor environments.

Aerosense Series CDT-100 Carbon Dioxide Transmitter
Series CDT-100 Carbon Dioxide Transmitter

Series CDT-100, Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct the measurements.

Measurement range upto 10000 ppm selectable by jumper. It gives analog and RS-485 MODBUS output and supports various functions like recalibration function.

Product Applications:

  • Demand Control Ventilation in schools, office buildings, hospitals and other indoor environments.
  • CO2 Sensor: NDIR (Non-Dispersive Infrared) technology
  • Analog Voltage/Current Output: (3-wired) 0/4-20Ma or 0/2-10V- settable by switch
  • RS-485 MODBUS output: (4-wired) Modicon MODBUS RTU mode, which follow Modicon Modbus protocol-settable address ID switch
  • Re-Calibration function: 10 minutes’ manual recalibration(MCDL) Or weekly auto-calibration (ACDL) are supported and settable by Switch CO2 ppm measurement range -settable by switch
  • Power: 24VDC, AC
  • Size: 123mmX70mmX43mm
  • Operating Temperature: -10 to 60˚C For -CS Models: -40 to 40˚C
  • Operating Humidity range: 0 to 95% RH
  • Storage temperature: -30 to 70˚C
  • Storage temperature for cold storage: -40 to 70˚C
  • Measurement range: 0 to 2000/ 3000/ 5000/ 10000 ppm (Selectable by Jumper)
  • Accuracy: ±30ppm ±3%
  • Response time: 150 seconds
  • Response time for cold storage: 70 seconds
  • Sampling interval: 3 sec
Model No.SpecificationsCDT-100Carbon Dioxide TransmitterCDT-100-LCDCarbon Dioxide Transmitter with displayCDT-100-CSCarbon Dioxide Transmitter for cold storageCDT-100-CS-LCDCarbon Dioxide Transmitter for cold storage with displayCDT-100-M

Carbon Dioxide Transmitter with MODBUS Communication

CDT-100-M-LCD

Carbon Dioxide Transmitter with MODBUS Communication & display

Request
Callback


Additional Information:

  • Production Capacity: http://www.dpengineers.in
  • Delivery Time: http://www.dpengineersindia.in
  • Packaging Details: http://www.dp-engineers.com
Yes! I am Interested
X

Product Videos

Watch More Videos

Explore More Products

View All Products




Reach Us
DP Sharma (Proprietor)
D.P.Engineers
X/852, Chand Mohalla, Street No.11, Gandhi Nagar
Gandhi Nagar Jheel, Delhi - 110031, India


Call Us


Send E-mail