Product Details:
Minimum Order Quantity | 5 Piece |
Brand | Dwyer |
Current Rating | 8.0-24" w.c |
Media Type | Gas |
Electrical Connection | Screw Terminals |
Contact Material | Gold |
Model Number | 1626-20 |
Application | Air and non-combustible,compatible gases |
Series 1620 Single Electric Switch, Range 8.0-24" w.c., .50 min. Deadband, 1.20 max. Deadband
High Reliability, Repetitive Accuracy within ±1%
Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has a single electric switch.
Caution: For Use Only With Air Or Compatible Gases.
SpecificationService | Air and non-combustible, compatible gases |
Temperature Limits | -30 to 130°F |
Range | 8.0-24.0" w.c. |
Pressure Limits | Max. 50 in. w.c. continuous, 2 psig surge |
Switch Type | Single-pole double throw (SPDT) |
Repeatability | ±1% |
Electrical Rating | 15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz |
Electrical Connections | 3 screw type, common, normally open and normally closed |
Process Connections | 1/8" female NPT |
Mounting Orientation | Diaphragm in vertical position |
Set Point Adjustment | Screw adjustment |
Weight | 3 lb 9.8 oz |
Agency Approvals | CE |
Additional Information:
Product Details:
Minimum Order Quantity | 5 Piece |
Brand | Dwyer USA |
Current Rating | .5-6.0" w.c. |
Media Type | Gas |
Contact System Type | SPDT |
Electrical Connection | Screw Terminals |
Contact Material | Gold |
Model Number | 1626-05 |
Application | Air Or Compatible Gases |
High Reliability, Repetitive Accuracy within ±1%
Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has a single electric switch.
Caution: For Use Only With Air Or Compatible Gases.
SpecificationService | Air and non-combustible, compatible gases |
Temperature Limits | -30 to 130°F |
Range | .5-6.0" w.c. |
Pressure Limits | Max. 50 in. w.c. continuous, 2 psig surge |
Switch Type | Single-pole double throw (SPDT) |
Repeatability | ±1% |
Electrical Rating | 15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz |
Electrical Connections | 3 screw type, common, normally open and normally closed |
Process Connections | 1/8" female NPT |
Mounting Orientation | Diaphragm in vertical position |
Set Point Adjustment | Screw adjustment |
Weight | 3 lb 9.8 oz |
Agency Approvals | CE |
Additional Information:
Product Details:
Brand | Dwyer |
Electrical Connection | Screw Terminals |
Model Number | 1627-05 |
Pressure Range | 0.5-6.0" WC |
Power/Voltage | 1/4 HP,250 VAC |
Usage/Application | Only With Air Or Compatible Gases.product Applications |
Switch Type | Two Single-Pole Double Throw (SPDT) |
Pressure Limits Max. | 50 in. w.c. Continuous,2 psig Surge |
High Reliability, Repetitive Accuracy within ±1%
Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has dual electric switches.Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Unit have diaphragm sealed motion take outs providing maximum protection against leakage.
Caution: For Use Only With Air Or Compatible Gases.
SpecificationService | Air and non-combustible, compatible gases |
Temperature Limits | -30 to 130°F |
Range | .5-6.0" w.c. |
Pressure Limits | Max. 50 in. w.c. continuous, 2 psig surge |
Switch Type | Two single-pole double throw (SPDT) |
Repeatability | ±1% |
Electrical Rating | 15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz |
Electrical Connections | 3 screw type, common, normally open and normally closed |
Process Connections | 1/8" female NPT |
Mounting Orientation | Diaphragm in vertical position |
Set Point Adjustment | Screw adjustment |
Weight | 3 lb 11.8 oz |
Agency Approvals | CE |
Additional Information:
Product Details:
Brand | Dwyer |
Contact System Type | SPDT |
Electrical Connection | Screw Terminals |
Model Number | 1627-10 |
Pressure Range | 2.0 - 11" WC |
Color | Golden |
Power/Voltage | 1/4 HP,250 VAC |
Usage/Application | Only With Air Or Compatible Gases.product Applications |
Electricla Connection | 3 Screw Type,Common,Normally Open And Normally Closed |
Mounting Orientation | Diaphragm in Vertical Position |
Temperature Limits | -30 to 130 DegreeF |
High Reliability, Repetitive Accuracy within ±1%
Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has dual electric switches.Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Unit have diaphragm sealed motion take outs providing maximum protection against leakage.
Caution: For Use Only With Air Or Compatible Gases.
SpecificationService | Air and non-combustible, compatible gases |
Temperature Limits | -30 to 130°F |
Range | 2.0-11" w.c. |
Pressure Limits | Max. 50 in. w.c. continuous, 2 psig surge |
Switch Type | Two single-pole double throw (SPDT) |
Repeatability | ±1% |
Electrical Rating | 15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz |
Electrical Connections | 3 screw type, common, normally open and normally closed |
Process Connections | 1/8" female NPT |
Mounting Orientation | Diaphragm in vertical position |
Set Point Adjustment | Screw adjustment |
Weight | 3 lb 11.8 oz |
Agency Approvals | CE |
Additional Information:
Product Details:
Brand | Dwyer |
Contact System Type | SPDT |
Electrical Connection | Screw Terminals |
Model Number | 1627-1 |
Pressure Range | .15-1.5" W.C. |
Power/Voltage | 120-480 VAC |
Usage/Application | Only With Air Or Compatible Gases.product Applications |
Switch Type | Two Single-Pole Double Throw |
High Reliability, Repetitive Accuracy within ±1%
Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has dual electric switches.Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Unit have diaphragm sealed motion take outs providing maximum protection against leakage.
Caution: For Use Only With Air Or Compatible Gases.
SpecificationService | Air and non-combustible, compatible gases |
Temperature Limits | -30 to 130°F |
Range | 0.15-1.5" w.c. |
Pressure Limits | Max. 50 in. w.c. continuous, 2 psig surge |
Switch Type | Two single-pole double throw (SPDT) |
Repeatability | ±1% |
Electrical Rating | 15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz |
Electrical Connections | 3 screw type, common, normally open and normally closed |
Process Connections | 1/8" female NPT |
Mounting Orientation | Diaphragm in vertical position |
Set Point Adjustment | Screw adjustment |
Weight | 3 lb 11.8 oz |
Agency Approvals | CE |
Additional Information:
Product Details:
Brand | Dwyer |
Range Setting | 8.0-24" W.C |
Contact System Type | SPDT |
Electrical Connection | Screw Terminals |
Model Number | 1627-20 |
Electrical Rating | 120-480 VAC |
Temperature Limits | -30 to 130 DegreeF |
Process Connections | 1/8" female NPT |
Series 1620 Single Electric Switch, Range 8.0-24" w.c., .50 min. Deadband, 1.20 max. Deadband
High Reliability, Repetitive Accuracy within ±1%
Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model differential pressure switches are identical in design and construction has dual electric switches.Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Unit have diaphragm sealed motion take outs providing maximum protection against leakage.
Caution: For Use Only With Air Or Compatible Gases.
SpecificationService | Air and non-combustible, compatible gases |
Temperature Limits | -30 to 130°F |
Range | 8.0-24" w.c. |
Pressure Limits | Max. 50 in. w.c. continuous, 2 psig surge |
Switch Type | Two single-pole double throw (SPDT) |
Repeatability | ±1% |
Electrical Rating | 15A @ 120-480 VAC, 60 Hz. Resistive, 1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz |
Electrical Connections | 3 screw type, common, normally open and normally closed |
Process Connections | 1/8" female NPT |
Mounting Orientation | Diaphragm in vertical position |
Set Point Adjustment | Screw adjustment |
Weight | 3 lb 11.8 oz |
Agency Approvals | CE |
Additional Information:
Product Details:
Minimum Order Quantity | 5 Piece |
Application | Damper positioning Duct air control |
Brand | Dwyer |
Media Type | Gas |
Range Setting | .15-1.5" w.c |
Electrical Connection | Screw Terminals |
Contact Material | Gold |
Power/Voltage | 15 A @ 120-480 VAC |
Usage/Application | Air and non-combustible,compatible gases |
On the Series 1620 Single and Dual Pressure Switch, our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model 1626 and 1627 differential pressure switches are identical in design and construction except that Model 1626 has a single electric switch and Model 1627 has dual electric switches. Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Both units have diaphragm sealed motion take outs providing maximum protection against leakage.
CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.
Product ApplicationsFeatures
Additional Information:
Product Details:
Minimum Order Quantity | 5 Piece |
Brand | Dwyer USA |
Current Rating | 2.0-11" W.C |
Media Type | Gas |
Electrical Connection | Screw Terminals |
Contact Material | Gold |
Model Number | 1626-10 |
Application | Damper positioning Duct air control |
The Dwyer 1626-10 Single and Dual Pressure Switch has a range of 2.0-11" w.c. 10 min. deadband, 20 max. deadband, and 0.5 adj. diff. between set points.
Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model 1626 and 1627 differential pressure switches are identical in design and construction except that Model 1626 has a single electric switch and Model 1627 has dual electric switches. Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Both units have diaphragm sealed motion take outs providing maximum protection against leakage.
CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.
Product ApplicationsFeatures
Up to 3900 readings can be saved
Additional Information:
Product Details:
Minimum Order Quantity | 5 Piece |
Brand | Dwyer USA |
Media Type | Gas |
Range Setting | .15-1.5" w.c |
Electrical Connection | Screw Terminals |
Contact Material | Gold |
Model Number | 1626-1 |
Application | Damper positioning Duct air control |
I Deal In | New Only |
The Dwyer 1626-1 Single and Dual Pressure Switch has a range of .15-1.5" w.c., 10 min. deadband, 20 max. deadband, and 0.5 adj. diff. between set points.
Our old faithful switch design is still best where highest precision combined with diaphragm sealed leak proof construction and mounting simplicity are required. Model 1626 and 1627 differential pressure switches are identical in design and construction except that Model 1626 has a single electric switch and Model 1627 has dual electric switches. Model 1627 can therefore provide dual control when required. It can be set to open or close two independent electrical circuits, each preset for its own actuation pressure. Both units have diaphragm sealed motion take outs providing maximum protection against leakage.
CAUTION: FOR USE ONLY WITH AIR OR COMPATIBLE GASES.
Product ApplicationsFeatures
Up to 3900 readings can be saved
Additional Information: