GEMTECH SERIES 3000 DIGITAL PRESSURE GAUGE PASCAL

GEMTECH SERIES 3000 DIGITAL PRESSURE GAUGE PASCAL Wholesale Delhi NCR INDIA

GEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 2500 PASCAL

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Power Source24 VDC
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberGEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 2500 PASCAL
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
BrandsGEMTECH
GEMTECH Digital Pressure Gauge HSN CODE90262000

Minimum order quantity: 12 Piece

GEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 2500 PASCALThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 10000 PASCAL

₹ 18500/Piece Get Latest Price

Product Brochure
Power Source24 VDC
Dial Size4 inch / 100 mm
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberGEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 10000 PASCAL
Accuracy Class1
Window MaterialAcrylic
Wetted PartsStainless Steel
Part TypeGEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 10000 PASCAL
Product Weight250 g
GEMTECH Digital Pressure Gauge RANGE90262000
BrandsGEMTECH
Voltage24 VDC

Minimum order quantity: 12 Piece

GEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 10000 PASCALThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH Series 3000 Digital Pressure Gauge Range 30-0-30 PAC

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberGEMTECH Series 3000 Digital Pressure Gauge Range 30-0-30 PAC
Accuracy Class1
Window MaterialAcrylic
Measuring RangeGEMTECH Series 3000 Digital Pressure Gauge Range 30-0-30 PAC
GEMTECH Digital Pressure Gauge HSN CODE90262000
BrandsGEMTECH

Minimum order quantity: 12 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 30-0-30 PACThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH Series 3000 Digital Pressure Gauge Range 60-0-60 PAC

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Model Name/NumberGEMTECH Series 3000 Digital Pressure Gauge Range 60-0-60 PAC
Accuracy Class1
Window MaterialAcrylic
GEMTECH Digital Pressure Gauge HSN CODE90262000
BrandsGEMTECH

Minimum order quantity: 12 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 60-0-60 PACThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 750 PAC

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingStainless Steel
Model Name/NumberGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 750 PAC
Accuracy Class1
Window MaterialSafety Glass
GEMTECH Digital Pressure Gauge90262000
BrandsGEMTECH
Power24 VDC
Product Weight250 g

Minimum order quantity: 12 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 750 PAC
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve You

MATTERS NEEDING ATTENTION:
Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In Time
RELEVANT MATTERS BEFORE USE DELIVERY INSPECTION

Each Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The Transportation

APPLICATIONS AND FEATURES

Using High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation Methods
Various Measuring Ranges
No Moving Parts,Anti-Vibration
Accuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)
Button Function:Zero Calibration,Unit Switching
STORAGE AND INSTALLATION
The Product Should Be Kept In a Dry And Grime Free Place
Storage Temperature:-10℃~+40℃
Storage Humidity:0%~90%.
Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) Max
Avoid Storing in Corrosive Gas And Liquid Environment.
It is Best to Store It Properly Packaged On a Shelf Or Table
If it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricity
Ambient Temperature:-10~+50℃ (14~104℉)
Ambient Relative Humidity:<90%,no frost
Installation Height:<1000m
On a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports with
On the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The Other

PRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive Gas
Medium Temperature: 0-60°C
Shell:ABS Engineering Plastic
Working Environment:-20°C~+85°C
Differential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FS
Long-Term Stability:±0.1% FS/Year
Temperature Drift Coefficient: <0.03% FS/°C
Power Supply:4 AA Batteries

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 100 MM WC

₹ 18500/Piece Get Latest Price

Product Brochure
Power Source24 VDC
Dial Size4 inch / 100 mm
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberSeries 3000
Accuracy Class1
Window MaterialPoly carbonate
GEMTECH Digital Pressure Gauge HSN CODE90262000
Product Weight250 g

Minimum order quantity: 12 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 100 MM WC
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using

If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve You
MATTERS NEEDING ATTENTION:
Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self
Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets
When The Battery Voltage Is Low,Please Replace The Battery In Time

RELEVANT MATTERS BEFORE USE 
DELIVERY INSPECTION


Each Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The Transportation
APPLICATIONS AND FEATURES

Using High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure
Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems
Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure
Suitable For Embedded Installation,Flat Installation And Other Installation Methods
Various Measuring Ranges
No Moving Parts,Anti-Vibration
Accuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)
Button Function:Zero Calibration,Unit Switching
STORAGE AND INSTALLATION
The Product Should Be Kept In a Dry And Grime Free Place
Storage Temperature:-10℃~+40℃
Storage Humidity:0%~90%.
Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) Max
Avoid Storing in Corrosive Gas And Liquid Environment.
It is Best to Store It Properly Packaged On a Shelf Or Table
If it is used in an open package and it exceeds 3 months,The ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricity
Ambient Temperature:-10~+50℃ (14~104℉)
Ambient Relative Humidity:<90%,no frost
Installation Height:<1000m
On a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports with
On the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The Other


PRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive Gas
Medium Temperature: 0-60°C
Shell:ABS Engineering Plastic
Working Environment:-20°C~+85°C
Differential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FS
Long-Term Stability:±0.1% FS/Year
Temperature Drift Coefficient: <0.03% FS/°C
Power Supply:4 AA Batteries

Gemtech - Series 3000 Digital Pressure Gauge Range 0 To 500 Pascal- Sonarpur,West Bengal India

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Power Source24 VDC
Pressure Rangepharmaceutical,Hotel,Malls,Hospital,OT,POWER PLANT,CEMENT PLANT,STEEL PLANT,FERTILIZER,TEXTILE,Pharm
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberGEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 500 PASCAL-
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
Part TypeGEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 500 PASCAL- Sonarpur,West Bengal India
Product Weight250 g
GEMTECH Digital Pressure Gauge HSN CODE90262000

Minimum order quantity: 12 Piece

GEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 500 PASCAL- Sonarpur,West Bengal IndiaThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 1000 PASCAL

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Power Source24 VDC
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingStainless Steel
Model Name/NumberGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 1000 PASCAL
Accuracy Class1
Window MaterialAcrylic
Wetted PartsStainless Steel
Protection TypeGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 1000 PASCAL
Part TypeGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 1000 PASCAL
GEMTECH Digital Pressure Gauge HSN CODE90262000

Minimum order quantity: 12 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 1000 PASCALThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 250 PASCAL in Bawal

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Power Source24 VDC
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 250 PASCAL in Bawal
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
GEMTECH Digital Pressure Gauge HSN CODE90262000
Protection TypeGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 250 PASCAL in Bawal
Part TypeGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 250 PASCAL in Bawal
BrandsGEMTECH

Minimum order quantity: 12 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 250 PASCAL in BawalThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 125 PASCAL

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Power Source24 VAC
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingStainless Steel
Model Name/NumberGEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 125 PASCAL
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
Protection TypeGEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 125 PASCAL
Product Weight250 g
Voltage24 VAC
GEMTECH Digital Pressure Gauge HSN CODE90262000
Part TypeGEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 125 PASCAL

Minimum order quantity: 12 Piece

GEMTECH - Series 3000 Digital Pressure Gauge Range 0 to 125 PASCAL Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH Series-3000 Digital Pressure Gauge Range 0 to 3000 PASCAL

₹ 18500/Piece Get Latest Price

Product Brochure
Power Source24 VDC
Dial Size4 inch / 100 mm
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberGEMTECH Series-3000 Digital Pressure Gauge Range 0 to 3000 PASCAL
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
Product Weight250 g
GEMTECH Digital Pressure Gauge HSN CODE90262000
Frequency RangeGEMTECH Series-3000 Digital Pressure Gauge Range 0 to 3000 PASCAL
Max PressureGEMTECH Series-3000 Digital Pressure Gauge Range 0 to 3000 PASCAL
BrandsGEMTECH

Minimum order quantity: 12 Piece

GEMTECH Series-3000 Digital Pressure Gauge Range 0 to 3000 PASCAL Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 2000 PASCAL

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Power Source24 VDC
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 2000 PASCAL
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
GEMTECH Digital Pressure Gauge HSN CODE90262000
BrandsGEMTECH

Minimum order quantity: 12 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 2000 PASCAL Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 60 PASCAL

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Power Source24 VDC
Pressure Rangein WC / mmWC / MBAR / KPA / PA
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
Material of CasingStainless Steel
Model Name/NumberGEMTECH Series 3000 Digital Pressure Gauge Range 0 to 60 PASCAL
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
Usage/ApplicationHVAC Air Velocity Measurements
GEMTECH Digital Pressure Gauge HSN CODE90262000
BrandsGEMTECH

Minimum order quantity: 12 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 60 PASCALThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

930.80,930.81,930.82,930.83,930.85,930.86 Gemtech Diff. Pressure Switch In Budhera Village Gurgaon

₹ 1650/Piece Get Latest Price

Media TypeGas
Pressure Switch TypeElectromechanical Pressure Switch
Contact MaterialSilver
WeightWith Cover 150g,Witout Cover 110g
Mounting TypeDiaphragm in Vertical Position
Minimum Order Quantity24
GEMTECH Differential Pressure Switch HSN CODE852365090
Model Number930.80 930.81 930.82 930.83 930.85 930.86
Series930.8x
MediumAir,Non-Combustible And Non-Aggressive Gases
Maximum Operating Pressure10 kPa For all Pressure Ranges
Country of OriginMade in India

930.80,930.81,930.82,930.83,930.85,930.86 Gemtech Diff. Pressure Switch In Budhera Village Gurgaon 
GEMTECH Differential Pressure Switch 930.8x With Adjustable Switching Pressure
Applications

GEMTECH Adjustable Differential Pressure For Switch  Monitoring Overpressure,Vacuum and Differential Pressure Of Air Or Other Non-Combustible,Non-Aggressive Gases.Possible Fields Of Application IncludeMonitoring Air Filters And Ventilators,Monitoring Industrial Cooling-Air Circuits,Overheating Protection For Fan Heaters,Monitoring Flows in Ventilation Ducts,Controlling Air Fire-Potection Flaps,Frost Protection For Heat Exchangers 

Versions
With This Pressure Switch The Switching Pressure Can Be Adjusted Without A Pressure Gauge Using A Scaled Adjustment Knob.The Switching Differential Can Also Be Adjusted With A Screwdriver

Type

Adjustment Range For Upper Switching Pressure

From            To

Switching Differential

 Set To         

Tolerance For Upper And Lower Switching Pressure

930.80

20    200Pa

10Pa

±15%

930.81

30    300Pa

20Pa

±15% 

930.82

50     500Pa

20Pa

±15%

930.83

200    1000Pa

100Pa

±15%

930.85

500    2500Pa

150Pa

±15%

930.86

1000  4000Pa

250Pa

±15%

Switching Pressure Specifications Apply To Vertical Installation Which Is Also The Recommended Position With Pressure-Pipe Connections Pointing Downwards.If The Switches Are Installed Horizontally With AMP Connection Terminals Uppermost,The Switching Values Are Approx.20Pa Higher
Maximum Operating Pressure:10 kPa  For all Pressure Ranges
Medium:Air,Non-Combustible And Non-Aggressive Gases
Temperature Range:Medium And Ambient Temperature From-20'Cto +85'C,Storage Temperature From-40'Cto+85'C
Diaphragm Material:Silicone,Temperedat 200���,Free Of Gas Emissions.Other N Materials Availabe On Request
Pressure Connections:2 Plastic Pipe Connection Pieces (Pl And P2), External Diameter 6.0 MM,Pl For Connection To Higher Pressure (Marked+J,P2 For Connection To Lower Pressure Marked
Housing Materials:Switch Body Made Of PA 6.6.Cover Made Of PS
Weight:With Cover 150g,Witout Cover 110g
Mechanical Working Life:Over lO'Switcing Operations

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 750 PA In Pahuchibari Nashik Maharashtra

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
Display Digits4
UsePharmaceutical Industries
Display TypeDigital
Pressure TypeDifferential Pressure
Power Source16 - 28 VDC / AC
Connection TypeID tubing
Connection Size5 mm
Dial TypeDry
MountingBack
Material of CasingPlastic
Model Name/NumberGEMTECH Series 3000
Accuracy Class1
Window MaterialPoly carbonate
BrandsGEMTECH
Product Weight250 G
Power24 VDC
GEMTECH Digital Pressure Gauge90261090
Pressure Rangein WC / mmWC / MBAR / KPA / PA

Minimum order quantity: 15 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 750 PA In Pahuchibari Nashik Maharashtra
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve You

MATTERS NEEDING ATTENTION:

Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In Time

RELEVANT MATTERS BEFORE USE 
DELIVERY INSPECTION


Each Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The Transportation

APPLICATIONS AND FEATURES

Using High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation Methods
Various Measuring Ranges
No Moving Parts,Anti-Vibration
Accuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)
Button Function:Zero Calibration,Unit Switching
STORAGE AND INSTALLATION
The Product Should Be Kept In a Dry And Grime Free Place
Storage Temperature:-10℃~+40℃
Storage Humidity:0%~90%.
Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) Max
Avoid Storing in Corrosive Gas And Liquid Environment.
It is Best to Store It Properly Packaged On a Shelf Or Table
If it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricity
Ambient Temperature:-10~+50℃ (14~104℉)
Ambient Relative Humidity:<90%,no frost
Installation Height:<1000m
On a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports with
On the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The Other


PRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive Gas
Medium Temperature: 0-60°C
Shell:ABS Engineering Plastic
Working Environment:-20°C~+85°C
Differential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FS
Long-Term Stability:±0.1% FS/Year
Temperature Drift Coefficient: <0.03% FS/°C
Power Supply:4 -20 mA

GEMTECH Series 3000 Digital Pressure Gauge With Alarm Range 0 to 1000 Pa in Bhanpura Mandsaur (MP)

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
UsePharmaceutical Industries
Pressure TypeDifferential Pressure
Accuracy+ 1 % FS
Measuring Range0 - 1000 PA
Usage/ApplicationFan, Blower, Filter, Furnace Draft And Orifice Plate, Biological Safety Cabinet, Clean Bench, Etc
Display Type4 Bits LCD 18 mm Character Height With Units Indication
BrandGEMTECH
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
MaterialPlastic
Model Name/NumberGEMTECH Series 3000
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
GEMTECH Series 3000 Digital Pressure Gauge HSN CODE90261090
Pressure Rangein WC / mmWC / MBAR / KPA / PA

Minimum order quantity: 6 Piece

GEMTECH Series 3000 Digital Pressure Gauge With Alarm Range 0 to 1000 Pascal In Bhanpura Mandsaur Madhya Pradesh India
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using 
If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve You
MATTERS NEEDING ATTENTION:
Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In Time
RELEVANT MATTERS BEFORE USE DELIVERY INSPECTION

Each Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment.After Opening The Box,Please Check Whether The Product Caused Damage During The Transportation

APPLICATIONS AND FEATURES

Using High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation Methods
Various Measuring Ranges
No Moving Parts,Anti-Vibration
Accuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)
Button Function:Zero Calibration,Unit Switching
STORAGE AND INSTALLATION
The Product Should Be Kept In a Dry And Grime Free Place
Storage Temperature:-10℃~+40℃
Storage Humidity:0%~90%.
Vibration:20Hz:9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) Max
Avoid Storing in Corrosive Gas And Liquid Environment.
It is Best to Store It Properly Packaged On a Shelf Or Table
If it is Used in an Open Package And It Exceeds 3 Months,The Ambient Temperature Of The Storage Environment Should Not Be Higher Than 30 ℃.This is Because When The Electrolytic Capacitor is Stored Without Electricity,its Characteristics Are Easily Deteriorated When The Ambient Temperature Is Too High.Do Not Leave It For More Than a Year Without Electricity
Ambient Temperature:-10~+50℃ (14~104℉)
Ambient Relative Humidity:<90%,no frost
Installation Height:<1000m
On a Circle With a Diameter Of 105MM,Drill 3 Holes With an Average Angle of 120 Degrees.The Hole Diameter is Between 3-3.2 as Shown In The Picture Above). Mounted on The Surface With Accessory Screws M3X8.Choose One Pair of Pressure Ports To Connect to the Air Tube,Pay Attention to The Difference Between High and Low Pressure Ports,And Make Sure to Seal The Other Pair Of Pressure Ports With
On the plate that needs to be embedded,punch a hole, the diameter of the hole is Between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 Self-Tapping Screws.Choose one of The Pair of Pressure Ports to Connect to The Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The Other

PRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive Gas
Medium Temperature: 0-60°C
Shell:ABS Engineering Plastic
Working Environment:-20°C~+85°C
Differential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FS
Long-Term Stability:±0.1% FS/Year
Temperature Drift Coefficient: <0.03% FS/°C
Power Supply:4 -20 mA/24 VDC


GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 5000 PA in Sahibabad Industrial Area

₹ 18500/Piece Get Latest Price

Product Brochure
Dial Size4 inch / 100 mm
UsePharmaceutical Industries
Pressure TypeDifferential Pressure
Accuracy+ 1 % FS
Measuring Range0 - 5000 PA
Usage/ApplicationFan, Blower, Filter, Furnace Draft And Orifice Plate, Biological Safety Cabinet, Clean Bench, Etc
Display Type4 Bits LCD 18 mm Character Height With Units Indication
BrandGEMTECH
Connection TypeNPT
Connection Size1/8 inch
Dial TypeDry
MountingBack
MaterialPlastic
Model Name/NumberGEMTECH Series 3000
Accuracy Class1
Window MaterialPoly carbonate
Wetted PartsStainless Steel
GEMTECH Digital Pressure Gauge HSN CODE90261090
Pressure Rangein WC / mmWC / MBAR / KPA / PA

Minimum order quantity: 5 Piece

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 5000 PA in Sahibabad Industrial Area 
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using

If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve You
MATTERS NEEDING ATTENTION:
Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets
When The Battery Voltage Is Low,Please Replace The Battery In Time
RELEVANT MATTERS BEFORE USE DELIVERY INSPECTION

Each Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment.After Opening The Box,Please Check Whether The Product Caused Damage During The Transportation

APPLICATIONS AND FEATURES

Using High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation Methods
Various Measuring Ranges
No Moving Parts,Anti-Vibration
Accuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)
Button Function:Zero Calibration,Unit Switching
STORAGE AND INSTALLATION
The Product Should Be Kept In a Dry And Grime Free Place
Storage Temperature:-10℃~+40℃
Storage Humidity:0%~90%.
Vibration:20Hz:9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) Max
Avoid Storing in Corrosive Gas And Liquid Environment.
It is Best to Store It Properly Packaged On a Shelf Or Table
If it is Used in an Open Package And It Exceeds 3 Months,The Ambient Temperature Of The Storage Environment Should Not Be Higher Than 30 ℃.This is Because When The Electrolytic Capacitor is Stored Without Electricity,its Characteristics Are Easily Deteriorated When The Ambient Temperature Is Too High.Do Not Leave It For More Than a Year Without Electricity
Ambient Temperature:-10~+50℃ (14~104℉)
Ambient Relative Humidity:<90%,no frost
Installation Height:<1000m
On a Circle With a Diameter Of 105MM,Drill 3 Holes With an Average Angle of 120 Degrees.The Hole Diameter is Between 3-3.2 (as Shown In The Picture Above). Mounted on The Surface With Accessory Screws M3X8.Choose One Pair of Pressure Ports To Connect to the Air Tube,Pay Attention to The Difference Between High and Low Pressure Ports,And Make Sure to Seal The Other Pair Of Pressure Ports With
On the plate that needs to be embedded,punch a hole, the diameter of the hole is Between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 Self-Tapping Screws.Choose one of The Pair of Pressure Ports to Connect to The Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The Other

PRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive Gas
Medium Temperature: 0-60°C
Shell:ABS Engineering Plastic
Working Environment:-20°C~+85°C
Differential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FS
Long-Term Stability:±0.1% FS/Year
Temperature Drift Coefficient: <0.03% FS/°C
Power Supply:4-20 mA


GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 5000 PASCAL

₹ 18500/Piece Get Latest Price

Product Brochure

GEMTECH Series 3000 Digital Pressure Gauge Range 0 to 5000 PASCALThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTION:Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months,the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole,the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries

X

Contact Us

DP Sharma (Proprietor)
D.P.Engineers
X/852, Chand Mohalla, Street No.11, Gandhi Nagar
New Delhi - 110031, Delhi, India

Get Directions
Send Email
Share:
Thank youYour Enquiry has been sent successfully.