Manufacturer of a wide range of products which include gemtech series 3000 digital pressure gauge with alarm range 0 to 750 pascal in ghaziabad, gemtech series 3000 digital pressure gauge with alarm range 60-0-60 pascal in tirupati ap, gemtech series 3000 digital pressure gauge with alarm range 0 to 10000 pascal pandharpur, gemtech series 3000 digital pressure gauge with alarm range 0 to 5000 pascal, gemtech series 3000 digital pressure gauge with alarm range 0 to 2500 pascal amritsar (punjab) and gemtech 3000 digital pressure gauge with alarm range 0 to 1000 pascal in chirawa the royal city.
₹ 18500/Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 Vdc |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | +-1%FS, +-3%FS(0-60Pa),+-2%FS(0-125Pa) |
Mounting | Bottom |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 750 PASCAL in Ghaziabad |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Brand's | GEMTECH |
Product Weight | 250 g |
GEMTECH Digital Pressure Gauge | 90262000 |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 750 PASCAL in Ghaziabad
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC₹ 18500/Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 Vdc |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | +-1%FS, +-3%FS(0-60Pa),+-2%FS(0-125Pa) |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 60-0-60 PASCAL in Tirupati AP |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Product Weight | 250 g |
Brands | GEMTECH |
GEMTECH Digital Pressure Gauge | 90262000 |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 60-0-60 PASCAL in Tirupati Andhra PradeshThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | +-0.5% RH |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 10000 PASCAL Pandharpur |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Packaging Type | 1 BOX |
Brands | GEMTECH |
Part Type | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 10000 PASCAL Pandharpur |
Item | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 10000 PASCAL Pandharpur |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 10000 PASCAL Vitthal Temple,PandharpurThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Power Source | 24 VDC |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | +-0.5 % |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 5000 PASCAL |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Brands | GEMTECH |
GEMTECH Digital Pressure Gauge RANGE | 90262000 |
Country of Origin | Made in India |
Part Type | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 5000 PASCAL |
Product Weight | 250 g |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 5000 PASCAL Dealers|Wholesaler|Delhi|NCR|India|Bangalore|Mumbai|Kolkata|D.P.ENGINEERSThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Power Source | 24 VDC |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | +-0.5 % |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 2500 PASCAL Amritsar (Punjab) |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Brands | GEMTECH |
Part Type | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 2500 PASCAL Amritsar (Punjab) |
Product Weight | 250 g |
GEMTECH Digital Pressure Gauge RANGE | 90262000 |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 2500 PASCAL New Delhi to Amritsar (Punjab)Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Power Source | 24 VDC |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Gas |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | +0.5 % |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH 3000 Digital Pressure Gauge with Alarm Range 0 to 1000 PASCAL in Chirawa The Royal City |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Brands | GEMTECH |
Protection Type | GEMTECH 3000 Digital Pressure Gauge with Alarm Range 0 to 1000 PASCAL in Chirawa The Royal City |
Part Type | GEMTECH 3000 Digital Pressure Gauge with Alarm Range 0 to 1000 PASCAL in Chirawa The Royal City |
Product Weight | 250 g |
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 1000 PASCAL in Chirawa The Royal CityThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 VDC |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | +0.5 % |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 500 PASCAL Jalaun |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Part Type | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 500 PASCAL Jalaun |
Brands | GEMTECH |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Product Weight | 250 g |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 500 PASCAL अपनी हवेली JalaunThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 vdc |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | +0.5 % |
Mounting | Back |
Material of Casing | Stainless Steel |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 250 PASCAL Village Konch Dist Jalau |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Part Type | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 250 PASCAL Konch Dist Jalaun UP |
Shell | ABS Engineering Plastic |
Brands | GEMTECH |
Protection Type | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 250 PASCAL Konch Dist Jalaun UP |
Product Weight | 250 g |
Usage/Application | Air Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 250 PASCAL Village Konch Dist Jalaun UPThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 125 PASCAL Chiraiyakot,(UP) |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Product Weight | 250 g |
Part Type | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 125 PASCAL Chiraiyakot,(UP) |
Brands | GEMTECH |
Voltage | 24 VAC |
Accuracy | +-1 % |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Protection Type | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 125 PASCAL Chiraiyakot,(UP) |
Usage/Application | Air Flow Monitoring Across Centrifugal Fans And Blowers,In-Duct Air Flow Monitoring,VAV Applications |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 125 PASCAL Chiraiyakot,Uttar Pradesh,IndiaThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 3000 PASCAL Ashoknagar Kalyangarh |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Max Pressure | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 3000 PASCAL Ashoknagar Kalyangarh |
Brands | GEMTECH |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 3000 PASCAL Ashoknagar Kalyangarh - অশোকনগর কল্যাণগড়.
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 Vdc |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 2000 PASCAL in Kamaluaganja |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Product Weight | 250 g |
Max Pressure | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 2000 PASCAL in Kamaluaganja |
Brands | GEMTECH |
GEMTECH Digital Pressure Gauge HSN CODE | 90262000 |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 2000 PASCAL in KamaluaganjaThank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Power Source | 24 Vdc |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Use | Pharmaceutical Industries |
Display Type | Digital |
Pressure Type | Differential Pressure |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Range Accuracy | 0.5% |
Mounting | Back |
Material of Casing | Plastic |
Model Name/Number | GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 0 to 60 PASCAL in Navi Mumbai |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Wetted Parts | Stainless Steel |
Minimum order quantity: 12 Piece
GEMTECH | Series 3000 Digital Pressure Gauge with Alarm Range 0 to 60 PASCAL in Navi Mumbai
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
₹ 18500/Piece Get Latest Price
Dial Size | 4 inch / 100 mm |
Use | Pharmaceutical Industries |
Pressure Type | Differential Pressure |
Accuracy | + / - 1 % f.S. |
Measuring Range | 60-0-60 PA |
Usage/Application | Fan, Blower, Filter, Furnace Draft And Orifice Plate, Biological Safety Cabinet, Clean Bench, Etc |
Brand | GEMTECH |
Display Type | 4 Bits LCD 18 mm Character Height With Units Indication |
Connection Type | NPT |
Connection Size | 1/8 inch |
Dial Type | Dry |
Mounting | Back |
Material | Plastic |
Model Name/Number | CDPG -20L-LED |
Accuracy Class | 1 |
Window Material | Poly carbonate |
Power | 24 VDC |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge Range 60-0-60 PA in Darnasangvi Nashik Maharashtra
Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve You
MATTERS NEEDING ATTENTION:
Please Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In Time
RELEVANT MATTERS BEFORE USE DELIVERY INSPECTION
Each Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The Transportation
APPLICATIONS AND FEATURES
Using High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential Pressure Can Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic Systems Can Be Used On Medical Equipment To Monitor Blood And Respiratory Pressure Suitable For Embedded Installation,Flat Installation And Other Installation Methods
Various Measuring Ranges
No Moving Parts,Anti-Vibration
Accuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)
Button Function:Zero Calibration,Unit Switching
STORAGE AND INSTALLATION
The Product Should Be Kept In a Dry And Grime Free Place
Storage Temperature:-10℃~+40℃
Storage Humidity:0%~90%.
Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) Max
Avoid Storing in Corrosive Gas And Liquid Environment.
It is Best to Store It Properly Packaged On a Shelf Or Table
If it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricity
Ambient Temperature:-10~+50℃ (14~104℉)
Ambient Relative Humidity:<90%,no frost
Installation Height:<1000m
On a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports with
On the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The Other
PRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive Gas
Medium Temperature: 0-60°C
Shell:ABS Engineering Plastic
Working Environment:-20°C~+85°C
Differential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FS
Long-Term Stability:±0.1% FS/Year
Temperature Drift Coefficient: <0.03% FS/°C
Power Supply:4 -20 mA
₹ 18500/Piece Get Latest Price
Power Source | 24 Vdc |
Dial Size | 4 inch / 100 mm |
Pressure Range | in WC / mmWC / MBAR / KPA / PA |
Minimum order quantity: 12 Piece
GEMTECH Series 3000 Digital Pressure Gauge with Alarm Range 30-0-30 PASCAL for Bhadohi(Lok Sabha constituency)Thank You For Choosing Our Digital Differential Pressure Gauge.Please Read This Manual Before Using If You Have Any Doubt About The Use,Please Feel Free To Contact Our Company,We Are Quite Willing To Serve YouMATTERS NEEDING ATTENTIONPlease Do Not Modify The Internal Wiring And Lines Of The Digital Differential Pressure Gauge By Your Self Please Choose a Safe Area To Install The Digital Differential Pressure Gauge To Prevent High Temperature And Avoid Splashing Of Moisture And Water Droplets When The Battery Voltage Is Low,Please Replace The Battery In TimeRELEVANT MATTERS BEFORE USE DELIVERY INSPECTIONEach Differential Pressure Transmitter is Subject to Strict Quality Control Before Delivery.Product Packaging Adopts Enhanced Anti-Collision Treatment. After Opening The Box,Please Check Whether The Product Caused Damage During The TransportationAPPLICATIONS AND FEATURESUsing High-Precision Sensors And Digital Technology,Can Detect Positive Pressure,Negative Pressure Or Differential PressureCan Be Widely Used To Measure The Pressure Of Fans And Blowers Filter Resistance Wind Speed Furnace Ventilation Pressure Drop Caused By Orifice Plates,Liquid Level In Foaming Systems And Pressure In Booster Or Hydraulic SystemsCan Be Used On Medical Equipment To Monitor Blood And Respiratory PressureSuitable For Embedded Installation,Flat Installation And Other Installation MethodsVarious Measuring RangesNo Moving Parts,Anti-VibrationAccuracy Up To ±1%FS, ±3%FS(0-60Pa),±2%FS(0-125Pa)Button Function:Zero Calibration,Unit SwitchingSTORAGE AND INSTALLATIONThe Product Should Be Kept In a Dry And Grime Free PlaceStorage Temperature:-10℃~+40℃Storage Humidity:0%~90%.Vibration:20Hz: 9.8 m/s2 (1G) max;20Hz~50Hz:5.88 m/s2 (0. 6G) MaxAvoid Storing in Corrosive Gas And Liquid Environment.It is Best to Store It Properly Packaged On a Shelf Or TableIf it is used in an open package and it exceeds 3 months, the ambient temperature of the storage environment should not be higher than 30 ℃.This is because when the electrolytic capacitor is stored without electricity,its characteristics are easily deteriorated when the ambient temperature is too high.Do not leave it for more than a year without electricityAmbient Temperature:-10~+50℃ (14~104℉)Ambient Relative Humidity:<90%,no frostInstallation Height:<1000mOn a circle with a diameter of 105mm,drill 3 holes with an average angle of 120 degrees.The hole diameter is between 3-3.2 (as shown in the picture above). Mounted on The Surface With Accessory Screws M3X8.Choose one Pair of Pressure ports to connect to the Air Tube,Pay attention to the Difference Between High and Low Pressure Ports,And Make Sure to Seal the other pair of pressure ports withOn the plate that needs to be embedded,punch a hole, the diameter of the hole is between 114 and 3-114.8mm.Embed the product and install the accessory feet on the back.Then fix it on the plate with M3.5X50 self-tapping screws.Choose one of the pair of pressure ports to connect to the Airway Note the Difference Between High/Low Pressure Ports And Make Sure To Seal The OtherPRODUCT PARAMETERS Medium:Air And Non-Flammable,Non-Corrosive GasMedium Temperature: 0-60°CShell:ABS Engineering PlasticWorking Environment:-20°C~+85°CDifferential Pressure Range:a variety of Ranges.Overload 3xFS,Breaking pressure 10×FSLong-Term Stability:±0.1% FS/YearTemperature Drift Coefficient: <0.03% FS/°CPower Supply:4 AA Batteries/24 VDC
DP Sharma (Proprietor)
D.P.Engineers
X/852, Chand Mohalla, Street No.11, Gandhi Nagar
New Delhi - 110031, Delhi, India